Overview
PWM operating frequency: 15 kHz
Electrical isolation to heatsink (min.): 500 VAC
PWM operating frequency: 10 kHz
Maximum encoder frequency: 15 kHz
Maximum controller output frequency: 300 Hz
Heatsink overtemperature cutoff: linear cutback starts at 85°C; complete cutoff at 95°C
Heatsink undertemperature cutoff: complete cutoff at -40°C
CURTIS Model: 1238-6401
Nominal input voltage: 72V (default setting), 48V, 60V or 80V (84V)
2 Minute RMS Current Rating (amps): 450
S2-60 Minute RMS Current Rating (amps): 155
MOSFET overtemperature cutback: linear cutback starts at 100°C; complete cutoff at 110°C
MOSFET undertemperature cutback: approx. 50% motor current at -25°C; complete cutoff at -40°C
All low power connections are made through a single 35-pin AMPSEAL connector
Throttle Type: 0-5K Ω (default setting), flexible throttle circuitry accommodates a variety of throttle types: 5kΩ-0, 0-5kΩ, 0-5V, etc.
Operating Ambient Temperature Range: -40°C to 50°C
Internal Heatsink Operating Temperature Range: -40°C to 95°C
Storage Ambient Temperature Range: -40°C to 95°C
Package environmental rating: IP65
Dimensions: L275xW232xH85 mm
Net Weight: 6.82 kg
Features Include:
Increased Performance, Improved functionality
Higher performance form, fit and functional replacements for earlier CURTIS Model 1238 AC controllers.
CE marked as a programmable safety device under EN ISO 13849-1.
Models available for 450 output at 48-84V system voltages. These are true 2 minute RMS ratings, not short duration 'boost' ratings.
Enhanced 64MHz micro and additional FLASH memory doubles the available VCL code space and provides more than twice the VCL execution speed.
Six additional VCL-configurable CAN "mailboxes" significantly increases CAN master capabilities.
Advanced Pulse Width Modulation techniques produce low motor harmonics, low torque ripple and minimized heating losses, resulting in high efficiency.
Unmatched Flexibility
Easily programmable through the CURTIS Model 1313-4331 Handheld Programmer or 1314 PC Programming Station.
Programmable for either traction or pump applications.
Field upgradeable software.
Integrated Battery state-of-charge algorithm and hour meter.
Fully-featured generic software and VCL for typical Warehouse Truck applications is included.
Comprehensive programming options and VCL allow other applications to be easily supported.
CURTIS hand-held or PC Windows programming tools provide easy programming and powerful system diagnostic tools.
Integrated status LED provides instant diagnostic indication.
Robust Safety and Reliability
Dual Microprocessor architecture cross-checks critical circuits, logic, and software functions to ensure the highest possible functional safety performance level is achieved.
Insulated Metal Substrate power base provides superior heat transfer for increased reliability.
Fail-Safe power component design.
Reverse polarity protection on battery connections.
Short circuit protection on all output drivers.
Thermal cutback, warning, and automatic shutdown provide protection to motor and controller.
Rugged sealed housing and connectors meet IP65 environmental sealing standards for use in harsh environments.
Meets or complies with relevant US and International Regulations
EMC: Designed to the requirements of EN12895.
Safety: Designed to the requirements of:
EN1175-1:1998+A1:2010
EN (ISO) 13849-1
IP65 Rated per IEC 60529.
UL recognized per UL583.